LESSON 3: POWERTRAIN
Monitoring The Substrate Temperature Sensor
Substrate Temperature Sensor
The TCM controls a number of high power solenoids and is surrounded by automatic transmission fluid. As a
result, the TCM can get very hot. If the temperature of the hardware rises above a predetermined temperature, the
TCM shuts down. Prior to shutting down, the TCM logs a fault code and illuminates the MIL. Following the shut
down, the transmission enters a mechanical limp-home mode. Monitoring of the substrate temperature is carried
out by a temperature-dependent resistor mounted in the processor.
2005 Expedition/Navigator New Model Technician Training 02-SEP-04 3-61