PROBLEMS AND SOLUTIONS GUIDE
IMPORTANT!Ifyouexperienceaproblemwithyourvehicle,firstchecktheProblemsandSolutionsGuidebelow.Ifyoustill
experienceaproblem,pleasecontactPowerWheels
®
ConsumerRelations,toll-freeat1-800-348-0751 between 9 AM and 7 PM
(EST)MondaythroughFriday,and11AM-5PM(EST)Saturday.Or,contactyourlocalPowerWheels
®
authorized service center.
Forthelocationnearestyou,pleasevisituson-lineatwww.powerwheels.com,orcall1-800-348-0751.
PROBLEM POSSIBLE CAUSE SOLUTION
Vehicledoesnotrun Underchargedbattery Chargethebattery.Anewbatteryshouldhavebeenchargedfor
atleast18hoursbeforeusingthevehicleforthersttime.
Afterrst-timeuse,rechargethebatteryforatleast14hours
aftereachuse.Neverchargethebatterylongerthan30hours.
Checkallconnectors.Makesurethechargerconnectorisplugged
intothebatteryconnector,andthatthechargerispluggedinto
thewall.
Makesurepowerowtothewalloutletis“ON”.
Chargerisnotworking Thereisnosurewaytotellifyourchargerisworkingunlessyou
haveavoltmeter.Ifyoususpectthereisaproblemwithyour
charger,contactyourlocalPowerWheels
®
authorizedservice
center.Theycantestyourchargerforyou.
Trippedthermalfuse EachPowerWheels
®
6voltbatteryhasabuilt-inthermalfuse.
Athermalfusemay“trip”andshutdownoperationofthevehicle
ifthevehicleisoverloadedorthedrivingconditionstoosevere.
Onceafusehas"tripped",removeyourfootfromthepedaland
wait25secondsbeforeoperatingthevehicleagain.Toavoid
repeatedautomaticshutdowns,donotoverloadthevehicleby
exceedingthe65lb.maximumweightcapacityorbytowing
anythingbehindthevehicle.Donotdriveuphillsorrunintoxed
objects,whichcancausethewheelstostopspinningwhilepower
isstillbeingsuppliedtothemotors.Ifathermalfusecontinually
trips,contactyourlocalPowerWheels
®
authorizedservicecenter.
Loosewireorlooseconnectors Checkallwiresandconnectors.Makesurethemotorharness
connectorispluggedintothebatteryconnector,andthatthere
arenoloosewiresaroundthemotors.
Deadbattery IfyourbatteryisoldorifyouhavenotfollowedBatteryCare
instructions,yourbatterymaybedead.Ifyouareunsurewhether
ornotthebatteryisdead,youcanhaveittestedatyourlocal
PowerWheels
®
authorizedservicecenter.
Electricalswitchdamage Theelectricalswitchescanbecomecorrodedduetoexposureto
waterormoisture,orcanjamduetoloosedirt,sandorgravel.
ContactyourlocalPowerWheels
®
authorizedservicecenterfor
diagnosisandrepair.
Motordamage ContactyourlocalPowerWheels
®
authorizedservicecenterfor
diagnosisandrepair.